Human Asprosin ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.78 ng/ml (50 μl)
  • Standard Curve Range: 4.69~300 ng/ml
  • Standard Curve Gradient: 7 Points
  • Number of Incubations: 2
  • Sample Volume: 50 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 90min
  • Brand:
CAT.NO. : AEH0032
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
Asprosin is a new type of adipocytokine discovered by Romere et al. in 2016. It is mainly produced and secreted by white adipocytes, which can bind to the receptors on the surface of hepatocytes on the one hand, stimulate the glucose output of hepatocytes, and directly increase blood sugar; On the other hand, it can penetrate the blood-brain barrier, activate the neuronal activity of agRP gene-associated protein (AgRP) associated with feeding-related in the hypothalamic center, and inhibit the neuronal activity of anorexia-related opioid-melanocyte corticogen (POMC), promote food intake, and indirectly exert a hypoglycemic effect.
Typical data
pg/ml O.D. Average Corrected
0.00 0.0407 0.0468 0.0438  
4.69 0.1037 0.1032 0.1035 0.0597
9.38 0.1406 0.1638 0.1522 0.1085
18.75 0.2698 0.2895 0.2797 0.2359
37.50 0.5256 0.5766 0.5511 0.5074
75.00 1.0950 1.1600 1.1275 1.0838
150.00 2.3230 2.0280 2.1755 2.1318
300.00 3.6020 3.3780 3.4900 3.4463
Precision
Intra-assay Precision Inter-assay Precision
Sample Number S1 S2 S3 S1 S2 S3
22 22 22 6 6 6
Average(pg/ml) 6.4 29.6 112.8 5.9 31.2 118.1
Standard Deviation 0.3 1.2 5.9 0.3 1.3 5.4
Coefficient of Variation(%) 4 4 5.2 5.1 4.2 4.6

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 3.35-128.74 100 34.32

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of Asprosin in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.