Human CD273/B7-DA/PD-L2 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.01 ng/ml (50 μl);0.10 ng/ml (10 μl);
  • Standard Curve Range: 0.14~100 ng/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 75min
  • Brand:
CAT.NO. : AEHY0011
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
Programmed cell death 1 ligand 2 (PD-L2 or PDCD1 ligand 2) is also known as Butyrophilin B7-DC, CD antigen CD273, which belongs to the immunoglobulin superfamily or BTN/MOG family. The expression of PD-L2 is up-regulated by IFNG/IFN-gamma stimulation in monocytes and induced on dendritic cells grown from peripheral blood mononuclear cells with CSF2 and IL-4. PD-L2 Involved in the costimulatory signal, essential for T-cell proliferation and IFNG production in a PDCD1-independent manner. PD-L2 interaction with PDCD1 inhibits T-cell proliferation by blocking cell cycle progression and cytokine production.
typical data

ng/ml

O.D.

Average

Corrected

0.00

0.0077

0.0086

0.0082

 

0.14

0.0225

0.0239

0.0232

0.0151

0.41

0.0562

0.0586

0.0574

0.0493

1.23

0.1686

0.1711

0.1699

0.1617

3.70

0.5579

0.5243

0.5411

0.5330

11.11

1.6230

1.5880

1.6055

1.5974

33.33

3.4830

3.5050

3.4940

3.4859

100.00

4.3062

4.3968

4.3515

4.3434

precision

Intra-assay Precision

 

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(ng/ml)

2.0

10.6

29.4

1.8

10.1

29.2

Standard deviation

0.1

0.6

1.4

0.1

0.5

1.5

Coefficient of variation(%)

2.7

5.3

4.9

5.2

5.4

5.2


Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

spike recovery
The spike recovery was evaluated by spiking 3 levels of human CD273/B7-DC/PD-L2 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 89% to 120% with an overall mean recovery of 105%.
sample values

Sample Matrix

Sample

Evaluated

Range

(ng/ml)

Detectable

%

Mean of Detectable

(ng/ml)

Serum

30

5.48-15.01

100

9.93


Serum/Plasma - Thirty samples from apparently healthy volunteers were evaluated for the presence of human CD273/B7-DC/PD-L2 in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. | 浙ICP备2024113709号-3 Sitemap