HERC6 Rabbit Polyclonal Antibody

Key features and details

Rabbit polyclonal antibody to HERC6
  • Target: HERC6
  • Source/Host: Rabbit
  • Reactivity: Human, Mouse, Rat
  • Clonality: Polyclonal
  • Applications: WB,IHC,IF/ICC
  • Conjugation: Unconjugated
  • Isotype: IgG
  • Storage: at -20°C
  • Brand:
CAT.NO. : ARA5824
US$ Please choose
US$ Please choose
Size:
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
HERC6 (HECT and RLD domain containing E3 ubiquitin protein ligase family member 6) belongs to the HERC family of ubiquitin ligases, all of which contain a C-terminal HECT domain and at least one N-terminal RCC1-like domain (RLD). The HECT domain is predicted to catalyze the formation of a thioester with ubiquitin before transferring it to a substrate, and the RLD is predicted to act as a guanine nucleotide exchange factor for small G proteins. HERC6 is the major E3 ligase for ISG15 conjugation (ISGylation); it is interferon-inducible and acts as a positive regulator of the innate antiviral response. The protein localizes to the cytoplasm and cytosol, and is detected in brain, heart, placenta and testis.
Application
To ensure optimal assay performance, AREX recommends conducting reagent titration tailored to each testing system for optimal detection results.

Application

Dilution Ratio

WB

1:500 - 1:2000

IHC

1:100 - 1:500

IF/ICC

1:100 - 1:500

*Results are sample-specific. Please refer to your local assay conditions and test parameters for reference.
Overview

Description

HERC6 Rabbit Polyclonal Antibody for WB, IHC, IF

Specificity

Reacts with HERC6 in WB, IHC and IF applications. Shows reactivity with human, mouse and rat samples.

Immunogen

Synthetic peptide within human HERC6 amino acids 751-850 (total length 1,022 aa), conjugated to KLH.

Molecular Weight

Predicted: 115 kDa; Observed: 135 kDa

Purification

Protein A affinity purified.

Isotype

IgG

Form/Buffer

Liquid in 0.01M TBS (pH 7.4) with 1% BSA, 0.03% Proclin300 and 50% glycerol.

Subcellular Location

Cytoplasm, cytosol.

Alternative Names

HECT and RLD domain-containing E3 ubiquitin protein ligase 6, HECT domain and RCC1-like domain-containing protein 6, FLJ20637, HERC6

Gene Symbol

HERC6

Entrez Gene

55008

SwissProt

Q8IVU3

*AREX continuously optimizes our products. Webpage content may not reflect the latest updates. For inquiries, please contact info@arexbio.com or your local distributor.
*Clone Number, Reactivity, Source/Host and Clonality can be found in the product name and Key Features section above.
Data

Western blot analysis of HERC6 on different lysates with HERC6 Rabbit Polyclonal Antibody at 1/1,000 dilution. Lane 1: Mouse placenta tissue lysate; Lane 2: Mouse testis tissue lysate; Lane 3: Rat placenta tissue lysate; Lane 4: Rat testis tissue lysate; Lane 5: Human HL-60 cell lysate; Lane 6: Human A431 cell lysate; Lane 7: Human MOLT4 cell lysate. The blot was probed with IRDye800CW goat anti-rabbit IgG secondary antibody at 1/20,000 dilution. Predicted band size: 115 kDa; observed band size: 135 kDa.

Immunohistochemical analysis of paraformaldehyde-fixed, paraffin-embedded rat brain tissue with HERC6 Rabbit Polyclonal Antibody at 1:400 dilution overnight at 4°C, followed by detection with a rabbit SP kit and DAB staining. Antigen retrieval was performed by boiling in sodium citrate buffer (pH 6.0) for 15 minutes, endogenous peroxidase was blocked with 3% hydrogen peroxide for 20 minutes, and sections were blocked with normal goat serum at 37°C for 30 minutes.

Storage
Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
Note
For Research Use Only. Not for diagnostic, therapeutics, prophylactic or in vivo use.
FAQs
What are the main types of research antibodies and how do they differ?
Research antibodies are mainly divided into monoclonal antibodies and polyclonal antibodies. Monoclonal antibodies typically offer higher specificity and better batch-to-batch consistency, while polyclonal antibodies often provide stronger affinity but may show more variation between batches. The choice depends on your specific experimental needs.
How can I tell if a research antibody is suitable for my experiment?
It is recommended to carefully review the product datasheet for validated applications, species reactivity, recommended dilutions, and published references. For new antibodies, performing a small-scale validation with positive control samples is usually helpful.
Can improper storage of research antibodies affect experimental results?
Yes. Antibodies are sensitive to temperature, repeated freeze-thaw cycles, and contamination. Improper storage may lead to reduced activity, increased background, or weaker signals. It is best to follow the storage instructions provided in the product datasheet.
Why doesn’t the recommended dilution in the datasheet work well in my experiment?
The recommended dilution is based on the supplier’s test conditions. Factors such as sample type, fixation method, and detection system in your lab can influence the optimal working concentration. Performing a dilution series optimization in your own system is often necessary.
What precautions should I take when using a newly purchased research antibody for the first time?
It is advisable to briefly centrifuge the antibody (especially concentrated or lyophilized ones), then perform a small-scale pilot experiment using the recommended conditions. Recording the batch number and usage date is also helpful for future tracking.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. | 浙ICP备2024113709号-3 Sitemap