Human Adiponectin ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.15 pg/ml (50 μl);3.56 pg/ml (10 μl)
  • Standard Curve Range: 6.86~5000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0099
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
Adiponectin (also known as Adipocyte complement-related protein of 30 kDa, Acrp30) is an adipocyte-derived protein with wide ranging paracrine and endocrine effects on metabolism and inflammation. It promotes adipocyte differentiation, fatty acid catabolism, and insulin sensitivity and is negatively correlated with obesity, type 2 diabetes, and atherogenesis. Adiponectin associates into 70 kDa noncovalently-linked trimers that are disulfide-linked into medium molecular weight hexamers and then into >300 kDa high molecular weight oligomers
Typical Data

pg/ml

O.D.

Average

Corrected

0.00

0.0097

0.0102

0.0100

 

6.86

0.0277

0.0283

0.0280

0.0181

20.58

0.0665

0.0592

0.0629

0.0529

61.73

0.1897

0.1883

0.1890

0.1791

185.19

0.5615

0.5451

0.5533

0.5434

555.56

1.4160

1.4190

1.4175

1.4076

1666.67

2.8940

2.7930

2.8435

2.8336

5000.00

4.1026

4.1065

4.1046

4.0946

Precision

Intra-assay Precision

 

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

103.3

485.3

1632.6

111.5

520.8

1724.6

Standard deviation

2.8

27.8

81.6

5.8

31.7

128.9

Coefficient of variation(%)

2.7

5.7

5.0

5.2

6.1

7.5


  • Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
  • Inter-assay Precision (Precision between assays)Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human Adiponectin into health human serum sample. The un-spiked serum was used as blank in this experiment. The recovery ranged from 81% to 126% with an overall mean recovery of 93%.
Sample Values

Sample Matrix

Sample Evaluated

Range (ng/ml)

Detectable

%

Mean of Detectable (ng/ml)

Serum

30

2621.9-7072.8

100

4559.1


Serum/Plasma - Thirty samples from apparently healthy volunteers were evaluated for the presence of human Adiponectin in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.