Human Angiogenin ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.01 ng/ml (50 μl);0.07 ng/ml (10 μl);
  • Standard Curve Range: 0.41~100 ng/ml
  • Standard Curve Gradient: 7 Points
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 60min
  • Brand:
CAT.NO. : AEHY0190
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
Angiogenin (ANG) is a secreted protein that belongs to the pancreatic ribonuclease family. It was initially purified based on its ability to initiate vascularization in the chicken embryo chorioallantoic membrane from serum-free media conditioned by growth of a human adenocarcinoma cell line HT-29. A number of other tumors, as well as normal cell lines, also secrete Angiogenin. Angiogenin is present in normal human plasma.
Typical data

ng/ml

O.D.

Average

Corrected

0.00

0.0123

0.0123

0.0123

0.41

0.0423

0.0436

0.0430

0.0307

1.02

0.0915

0.0921

0.0918

0.0795

2.56

0.2093

0.2128

0.2111

0.1988

6.40

0.5093

0.5195

0.5144

0.5021

16.00

1.2320

1.2210

1.2265

1.2142

40.00

2.5030

2.4640

2.4835

2.4712

100.00

3.4960

3.4790

3.4875

3.4752

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(ng/ml)

2.2

9.9

34.2

2.4

10.6

35.4

Standard Deviation

0.1

0.1

0.6

0.0

0.2

0.6

Coefficient of Variation(%)

2.3

1.4

1.6

1.1

1.7

1.7

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human Angiogenin into health human serum sample. The un-spiked serum was used as blank in this experiment. The recovery ranged from 80% to 119% with an overall mean recovery of 96%
Sample Values
Sample Matrix Sample Evaluated Range (ng/ml) Detectable (%) Mean of Detectable (ng/ml)
Serum 30 115.46-277.38 100 168.44

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of Angiogenin in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.