Human B7-H2/CD257 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.01 pg/ml (50 μl);4.95 pg/ml (10 μl)
  • Standard Curve Range: 13.72~10000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0133
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
ICOSL protein (Inducible T-cell COStimulator Ligand), also known as B7h or CD275 protein, is a ligand of ICOS and belongs to one of the members of the B7 family. ICOSL is mainly expressed on the surface of antigen-presenting cells such as dendritic cells and B cells. The binding of ICOSL to ICOS can provide costimulatory signals that promote activation, proliferation and differentiation of T cells.
typical data

pg/ml

O.D.

Average

Corrected

0.00

0.0144

0.0126

0.0135

 

13.72

0.0336

0.0343

0.0340

0.0205

41.15

0.0807

0.0725

0.0766

0.0631

123.46

0.1894

0.2274

0.2084

0.1949

370.37

0.4951

0.5551

0.5251

0.5116

1111.11

1.2880

1.3600

1.3240

1.3105

3333.33

2.7260

2.8360

2.7810

2.7675

10000.00

4.1722

4.2258

4.1990

4.1855

precision

Intra-assay Precision

 

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

246.6

1218.8

4221.3

132.7

829.4

3607.5

Standard deviation

19.3

97.6

239.4

5.4

63.9

268.3

Coefficient of variation(%)

7.8

8.0

5.7

4.0

7.7

7.4


Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision
spike recovery

The spike recovery was evaluated by spiking 3 levels of human B7-H2/CD275 into health human serum sample. The un-spiked serum was used as blank in this experiment.

The recovery ranged from 72% to 107% with an overall mean recovery of 87%.

sample values

Sample Matrix

Sample

Evaluated

Range

(ng/ml)

Detectable

%

Mean of Detectable

(ng/ml)

Serum

30

0.07-193.97

100

106.56


Serum/Plasma - Thirty samples from apparently healthy volunteers were evaluated for the presence of B7-H2/CD275 in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.