Human CCL25 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.06 pg/ml (50 μl);0.32 pg/ml (10 μl)
  • Standard Curve Range: 1.37~1000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0117
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
CCL25 (thymus-expressed chemokine) is a novel CC chemokine that is distantly related (approximately 20% amino acid sequence identity) to other CC chemokines. Human CCL25 cDNA encodes a 150 amino acid residue precursor protein with a 23 amino acid residue signal peptide that is cleaved to yield a 127 residue mature protein. Mouse CCL25 cDNA has also been cloned and shown to encode a 144 amino acid protein that exhibits 49% amino acid sequence identity to human CCL25. The expresssion of human and mouse CCL25 was shown to be highly restricted to the thymus and small intestine. Although dendritic cells have been demonstrated to be the source of CCL25 production in the thymus, dendritic cells derived from bone marrow do not express CCL25. The gene for mouse CCL25 has been mapped to chromosome 8 rather than chromosome 11 where many mouse CC chemokines are clustered. Recombinant human and mouse CCL25 have been shown to be chemotactic for activated macrophages, dendritic cells and thymocytes. CCL25 has also been shown to be a specific agonist for the orphan receptor called GPR-9-6, now named CCR9.
Typical data
pg/ml O.D. Average Corrected
0.00 0.0067 0.0063 0.0065  
1.37 0.0212 0.0206 0.0209 0.0144
4.12 0.0535 0.0512 0.0524 0.0459
12.35 0.1545 0.1510 0.1528 0.1463
37.04 0.4450 0.4292 0.4371 0.4306
111.11 1.2110 1.2380 1.2245 1.2180
333.33 2.6520 2.6360 2.6440 2.6375
1000.00 4.0170 4.0352 4.0261 4.0196
Precision
Intra-assay Precision Inter-assay Precision
Sample Number S1 S2 S3 S1 S2 S3
  22 22 22 6 6 6
Average(pg/ml) 23.6 103.0 292.7 24.1 115.1 349.9
Standard Deviation 1.0 5.4 18.0 1.3 1.8 19.4
Coefficient of Variation(%) 4.4 5.3 6.2 5.3 1.6 5.5
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human CCL25 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 77% to 98% with an overall mean recovery of 84%.
Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 0.12-5.85 100 3.15
Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of CCL25 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.