Human CD147/EMMPRIN ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 1.44 pg/ml (50 μl);3.63 pg/ml (10 μl)
  • Standard Curve Range: 5.49~4000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0139
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
The name EMMPRIN reflects this proteins extracellular metalloproteinase inducer activity. It is a cell surface protein with two extracellular Ig domains, a transmembrane domain, and a cytoplasmic domain. Its expression is often elevated in human tumor cells, which in turn promotes MMP-1, MMP-2 and MMP-3 production in melanoma cells and MMP-2 and MMP-9 production in breast cancer cells. It interacts with several types of molecules such as integrins, caveolin-1 and MCT1. TRA-1-85 is an epitope within EMMPRIN.
typical data

pg/ml

O.D.

Average

Corrected

0.00

0.0094

0.0094

0.0094

 

5.49

0.0292

0.0303

0.0298

0.0204

16.46

0.0711

0.0747

0.0729

0.0635

49.38

0.2033

0.2031

0.2032

0.1938

148.15

0.5809

0.6104

0.5957

0.5863

444.44

1.4780

1.4830

1.4805

1.4711

1333.33

2.8760

2.7790

2.8275

2.8181

4000.00

3.9430

3.8660

3.9045

3.8951

Precision

Intra-assay Precision

 

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

112.4

569.7

1538.8

101.4

480.9

1376.3

Standard deviation

4.0

21.3

94.7

4.6

28.0

80.6

Coefficient of variation(%)

3.6

3.7

6.2

4.5

5.8

5.9

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human CD147/EMMPRIN into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 80% to 103% with an overall mean recovery of 86%.The spike recovery was evaluated by spiking 3 levels of human CD147/EMMPRIN into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 80% to 103% with an overall mean recovery of 86%.
Sample Values

Sample Matrix

Sample

Evaluated

Range

(pg/ml)

Detectable

%

Mean of Detectable

(pg/ml)

Serum

30

139.08-781.71

100

234.71


Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of CD147/EMMPRIN in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.