Human CD163 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 1.70 pg/ml (50 μl);7.17 pg/ml (10 μl);
  • Standard Curve Range: 0.14~100 ng/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0185
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
CD163, also known as M130 and p155, is a transmembrane scavenger receptor that is expressed on monocytes and macrophages and is inducible by immunosuppressant glucocorticoids and IL-10. A soluble form is shed from the cell surface by TACE or neutrophil elastase mediated cleavage in response to oxidative stress, Prostaglandin F2a stimulation, or the activation of Fc gamma receptors, TLR1, 2, 5, or 6. CD163 mediates monocyte binding to bacteria, leading to the release of inflammatory cytokines. It is essential for the circulatory clearance of hemoglobin-haptoglobin (Hb-Hp) complexes as well as free hemoglobin. It can also mediate monocyte-erythroblast adhesion and promote erythroblast expansion. CD163 binds and internalizes the cytokine TWEAK, and the ratio of soluble CD163 to TWEAK in the plasma is elevated during atherosclerosis.
Typical data

ng/ml

O.D.

Average

Corrected

0.00

0.0099

0.0093

0.0096

0.14

0.0621

0.0619

0.0620

0.0524

0.41

0.1733

0.1701

0.1717

0.1621

1.23

0.4638

0.4590

0.4614

0.4518

3.70

1.3069

1.2344

1.2707

1.2611

11.11

2.7103

2.6940

2.7022

2.6926

33.33

3.9264

3.9572

3.9418

3.9322

100.00

4.2301

4.2246

4.2274

4.2178

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(ng/ml)

2.2

10.7

33.5

2.1

9.9

47.0

Standard Deviation

0.1

0.5

1.9

0.1

0.4

2.7

Coefficient of Variation(%)

4.8

4.6

5.7

3.2

3.8

5.8

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human CD163 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 85% to 115% with an overall mean recovery of 100%.
Sample Values
Sample Matrix Sample Evaluated Range (ng/ml) Detectable (%) Mean of Detectable (ng/ml)
Serum 30 175.83-829.63 100 452.37

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of CD163 in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.