Human CD276/B7-H3 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.34 pg/ml (50 μl);1.64 pg/ml (10 μl)
  • Standard Curve Range: 6.86~5000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0101
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
B7 homolog 3 (B7-H3), a member of the immunoglobulin superfamily, is also known CD276, which contains two Ig-like C2-type (immunoglobulin-like) domains and two Ig-like V-type (immunoglobulin-like) domains. B7-H3 may participate in the regulation of T-cell-mediated immune response. B7-H3 also plays a protective role in tumor cells by inhibiting natural-killer mediated cell lysis as well as a role of marker for detection of neuroblastoma cells. Furthermore, B7-H3 is involved in the development of acute and chronic transplant rejection and in the regulation of lymphocytic activity at mucosal surfaces. It could also play a key role in providing the placenta and fetus with a suitable immunological environment throughout pregnancy
typical data

pg/ml

O.D.

Average

Corrected

0.00

0.0245

0.0188

0.0217

 

6.86

0.0357

0.0299

0.0328

0.0112

20.58

0.0549

0.0489

0.0519

0.0303

61.73

0.1073

0.1138

0.1106

0.0889

185.19

0.2891

0.2753

0.2822

0.2606

555.56

0.7364

0.7668

0.7516

0.7300

1666.67

1.7640

1.6930

1.7285

1.7069

5000.00

3.2980

3.2950

3.2965

3.2749

precision

Intra-assay Precision

 

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

100.5

499.3

1636.1

93.4

457.0

1443.3

Standard deviation

5.1

22.3

81.7

4.2

18.2

4.0

Coefficient of variation(%)

5.1

4.5

5.0

4.5

4.0

3.5


Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

spike recovery
The spike recovery was evaluated by spiking 3 levels of human CD276/B7-H3 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 90% to 120% with an overall mean recovery of 101%.
sample values

Sample Matrix

Sample Evaluated

Range (ng/ml)

Detectable

%

Mean of Detectable (ng/ml)

Serum

30

5.04-9.65

100

6.68


Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of CD276/B7-H3 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. | 浙ICP备2024113709号-3 Sitemap