Human CD276/B7-H3 ELISA Kit

pg/ml |
O.D. |
Average |
Corrected |
|
0.00 |
0.0245 |
0.0188 |
0.0217 |
|
6.86 |
0.0357 |
0.0299 |
0.0328 |
0.0112 |
20.58 |
0.0549 |
0.0489 |
0.0519 |
0.0303 |
61.73 |
0.1073 |
0.1138 |
0.1106 |
0.0889 |
185.19 |
0.2891 |
0.2753 |
0.2822 |
0.2606 |
555.56 |
0.7364 |
0.7668 |
0.7516 |
0.7300 |
1666.67 |
1.7640 |
1.6930 |
1.7285 |
1.7069 |
5000.00 |
3.2980 |
3.2950 |
3.2965 |
3.2749 |
Intra-assay Precision |
|
Inter-assay Precision |
|||||
Sample Number |
S1 |
S2 |
S3 |
S1 |
S2 |
S3 |
|
22 |
22 |
22 |
6 |
6 |
6 |
||
Average(pg/ml) |
100.5 |
499.3 |
1636.1 |
93.4 |
457.0 |
1443.3 |
|
Standard deviation |
5.1 |
22.3 |
81.7 |
4.2 |
18.2 |
4.0 |
|
Coefficient of variation(%) |
5.1 |
4.5 |
5.0 |
4.5 |
4.0 |
3.5 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
The recovery ranged from 90% to 120% with an overall mean recovery of 101%.
Sample Matrix |
Sample Evaluated |
Range (ng/ml) |
Detectable % |
Mean of Detectable (ng/ml) |
Serum |
30 |
5.04-9.65 |
100 |
6.68 |
Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of CD276/B7-H3 in this assay. No medical histories were available for the donors.