Human CDCP1 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 1.41 pg/ml (50 μl)
  • Standard Curve Range: 31.25~2000 pg/ml
  • Standard Curve Gradient: 7 Points
  • Number of Incubations: 2
  • Sample Volume: 50 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0083
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
CDCP1, also known as SIMA135, is a novel 140 kDa type I transmembrane glycoprotein with three CUB protein-protein interaction domains in its 635 aa extracellular region. The 148 aa cytoplasmic region contains canonical phosphorylation sites for Sre kinase family members and binding sites for SH3 domains. By alternative splicing, a secreted 310 aa residue form of CDCP1 also exists. The amino-terminal region of approximately 265 aa of the type I membrane CDCP1 can also be proteolytically cleaved. CDCP1 is found on the surface of epithelial and bone marrow-derived stem cells. The extracellular region of human CDCP1 shares 84% aa identity with that of the mouse protein.
Typical data
pg/ml O.D. Average Corrected
0.00 0.0241 0.0233 0.0237  
31.25 0.0716 0.0819 0.0768 0.0531
62.50 0.1091 0.1151 0.1121 0.0884
125.00 0.1978 0.2099 0.2039 0.1802
250.00 0.3730 0.3911 0.3821 0.3584
500.00 0.7124 0.7447 0.7286 0.7049
1000.00 1.3820 1.4660 1.4240 1.4003
2000.00 2.7060 2.8110 2.7585 2.7348
Precision
Intra-assay Precision Inter-assay Precision
Sample Number S1 S2 S3 S1 S2 S3
22 22 22 6 6 6
Average(pg/ml) 10.9 55 157.3 10 49.7 152
Standard Deviation 0.8 3.0 8.1 0.5 2.1 5.5
Coefficient of Variation(%) 7.1 5.4 5.1 5.4 4.2 3.6

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human CDCP1 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 79% to 120% with an overall mean recovery of 108%.
Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 96.09-307.20 100 196.05

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of IL-12/IL-23 p40 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.