Human CTGF/CCN2 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.07 ng/ml (50 μl);0.35 ng/ml (10 μl);
  • Standard Curve Range: 4.69~300 ng/ml
  • Standard Curve Gradient: 7 Points
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 60min
  • Brand:
CAT.NO. : AEHY0156
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
CTGF belongs to the CCN (CYR61/CTGF/NOV) family of secreted proteins that share a common multimodular organization. Each protein contains an IGF-binding protein domain, a von Willebrand factor type C domain, a thrombospondin type I domain, and a cysteine knot domain. The multimodular CTGF has the ability to bind multiple ligands and has numerous effects on development, differentation, and disease. The C-terminal cysteine knot motif contains the heparin and low density lipoprotein receptor (LDLR) binding sites that contribute to the adhesive and mitogenic properties of CTGF.
Typical data

ng/ml

O.D.

Average

Corrected

0.00

0.0068

0.0064

0.0066

4.69

0.0893

0.0926

0.0910

0.0844

9.38

0.2235

0.2204

0.2220

0.2154

18.75

0.4926

0.5205

0.5066

0.5000

37.50

1.0290

1.1290

1.0790

1.0724

75.00

1.9120

2.0470

1.9795

1.9729

150.00

2.9800

3.1140

3.0470

3.0404

300.00

3.5890

3.6480

3.6185

3.6119

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(ng/ml)

6.3

31.3

98.9

6.0

31.1

101.0

Standard Deviation

0.2

1.0

2.8

0.2

1.3

4.1

Coefficient of Variation(%)

3.6

3.3

2.9

3.8

4.2

4.1

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human CTGF/CCN2 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 88% to 105% with an overall mean recovery of 96%.
Sample Values
Sample Matrix Sample Evaluated Range (ng/ml) Detectable (%) Mean of Detectable (ng/ml)
Serum 30 12.33-36.79 100 23.86

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of CTGF/CCN2 in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.