Human CXCL1/GRO alpha ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 14.89 pg/ml (50 μl);32.67 pg/ml (10 μl)
  • Standard Curve Range: 20.48~5000 pg/ml
  • Standard Curve Gradient: 7 Points
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0054
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
CXCL1/GRO alpha, also known as KC in mouse and CINC-1 in rat, is a member of the CXC family of chemokines. Human CXCL1/GRO alpha is 107 amino acids (aa) in length with a predicted molecular weight of 11 kDa. The mouse and rat orthologs share 57% and 59% amino acid sequence identity with the human protein, respectively. Genome-wide analysis suggests that the protein encoded by the mouse Cxcl3 gene is homologous to human CXCL1/GRO alpha protein. Human CXCL1/GRO alpha can be cleaved into three isoforms CXCL1/GRO alpha (aa 4-73), CXCL1/GRO alpha (aa 5-73), and CXCL1/GRO alpha (aa 6-73) which show higher activity than the full length protein. CXCL1/GRO alpha is secreted by mast cells and macrophages whereupon it acts as a chemoattractant for neutrophils.
Typical data
pg/ml O.D. Average Corrected
0.00 0.0137 0.0129 0.0133  
20.48 0.0170 0.0161 0.0166 0.0033
51.20 0.0261 0.0234 0.0248 0.0115
128.00 0.0446 0.0443 0.0445 0.0312
320.00 0.1492 0.1474 0.1483 0.1350
800.00 0.4857 0.5021 0.4939 0.4806
2000.00 1.2570 1.2630 1.2600 1.2467
5000.00 2.2760 2.2510 2.2635 2.2502
Precision
Intra-assay Precision Inter-assay Precision
Sample Number S1 S2 S3 S1 S2 S3
22 22 22 6 6 6
Average(pg/ml) 119.3 509.0 1409.9 110.0 510.1 1498.1
Standard Deviation 9.4 39.3 109.4 5.4 27.0 100.4
Coefficient of Variation(%) 7.9 7.7 7.8 4.9 5.3 6.7

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human CXCL1 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 72% to 125% with an overall mean recovery of 101%.
Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 77.28-616.13 100 358.62

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of CXCL1 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.