Human EGF ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.12 pg/ml (50 μl);0.59 pg/ml (10 μl)
  • Standard Curve Range: 1.37~1000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0023
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
EGF (Epidermal Growth Factor) is expressed as a transmembrane protein that is proteolytically cleaved to generate soluble forms. It signals through EGF R/ErbB1 which heterodimerizes with ErbB2, ErbB3, or ErbB4 and can also associate with PDGF R beta and HGF R/c-MET. During development, EGF regulates thymocyte differentiation, neuroglia production, and adipocyte maturation. In the adult, EGF plays a role in mammary gland lactogenesis, fibroblast mitosis, dissociation of the extracellular matrix, and cell migration.
Typical data
pg/ml O.D. Average Corrected
0.00 0.0115 0.0121 0.0118  
1.37 0.0293 0.0297 0.0295 0.0177
4.12 0.0676 0.0683 0.068 0.0562
12.35 0.1633 0.1675 0.1654 0.1536
37.04 0.4536 0.4552 0.4544 0.4426
111.11 1.1453 1.1946 1.1700 1.1582
333.33 2.3065 2.4491 2.3778 2.3660
1000.00 3.2412 3.2825 3.2619 3.2501
Precision
Intra-assay Precision Inter-assay Precision
Sample Number S1 S2 S3 S1 S2 S3
22 22 22 6 6 6
Average(pg/ml) 13.2 61.3 217.8 20.4 105 347.9
Standard Deviation 0.5 4.1 6.6 1 5.3 19.3
Coefficient of Variation(%) 3.5 6.7 3 4.9 5.1 5.6

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human EGF into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 78% to 106% with an overall mean recovery of 93%.
Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 200.7-417.0 100 304.2

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of IL-8 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.