Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.76 pg/ml (50 μl);1.25 pg/ml (10 μl)
  • Standard Curve Range: 1.37~1000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0047
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
IL-33 (Interleukin-33) is released from physically damaged or necrotic cells. It triggers Th2-biased immune cell activation at sites of inflammation as well as regulatory T cell and M2 macrophage expansion. It additionally induces angiogenesis, promotes tumor cell migration and invasion, limits cardiac myocyte hypertrophy, and limits the development of atherosclerotic plaques. IL-33 signals through a receptor complex composed of ST2 and IL-1 RAcP. IL-1 RAcP also associates with IL-1 RI, IL-1 RII, IL-1 R6, and SCF R/c-kit. Soluble isoforms of ST2 and IL-1 RAcP function as decoy receptors that regulate IL-33 bioactivity.
Typical data
pg/ml O.D. Average Corrected
0.00 0.0254 0.0268 0.0261  
1.37 0.0326 0.0317 0.0322 0.0061
4.12 0.0475 0.0402 0.0439 0.0178
12.35 0.0736 0.0732 0.0734 0.0473
37.04 0.1710 0.1730 0.1720 0.1459
111.11 0.4827 0.4851 0.4839 0.4578
333.33 1.3800 1.3950 1.3875 1.3614
1000.00 3.6260 3.6220 3.6240 3.5979
Precision
Intra-assay Precision Inter-assay Precision
Sample Number S1 S2 S3 S1 S2 S3
22 22 22 6 6 6
Average(pg/ml) 22.7 109.9 312.7 23.1 111.8 322.4
Standard Deviation 1.0 3.4 14.9 1.1 1.8 7.6
Coefficient of Variation(%) 4.5 3.1 4.8 4.8 1.6 2.4

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human IL-33 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 99% to 127% with an overall mean recovery of 108%.
Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 n.d.-16.51 3 16.51

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of IL-8 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.