Human IL-7 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.62 pg/ml (10 μl)
  • Standard Curve Range: 2.74~2000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0045
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
IL-7 (Interleukin-7) is a cytokine that plays important roles in lymphocyte differentiation, proliferation, and survival. IL-7 is produced by stromal epithelial cells of the thymus, bone marrow, and intestines. It signals through a receptor complex composed of IL-7 R alpha/CD127 and the Common gamma Chain. gamma c is also a subunit of the receptors for IL-2, -4, -9, -15, and -21. IL-7 contributes to the maintenance of all naïve and memory T cells. It is required for optimal T cell-dendral cell interaction. In mouse, IL-7 activation of IL-7 R alpha is critical for both T cell and B cell lineage development, while in humans, it is required for T cell but not for B cell development.
Typical data
pg/ml O.D. Average Corrected
0.00 0.0139 0.0144 0.0142  
2.74 0.0221 0.0202 0.0212 0.0070
8.23 0.0347 0.0347 0.0347 0.0210
24.69 0.0817 0.0730 0.0774 0.0630
74.07 0.2122 0.1976 0.2049 0.1910
222.22 0.6447 0.5979 0.6213 0.6070
666.67 1.6810 1.5880 1.6345 1.6200
2000.00 3.7070 3.5910 3.6490 3.6350
Precision
Intra-assay Precision Inter-assay Precision
Sample Number S1 S2 S3 S1 S2 S3
22 22 22 6 6 6
Average(pg/ml) 40.2 198.2 606.4 41.1 221.2 654.7
Standard Deviation 2.1 11.2 19.1 2.4 10.6 21.7
Coefficient of Variation(%) 5.3 5.6 3.1 5.9 4.8 3.3

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery

The spike recovery was evaluated by spiking 3 levels of human IL-7 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 80% to 96% with an overall mean recovery of 88%.

Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 n.d.-30.80 25 10.94

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of IL-8 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.