Human MICA ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 8.30 pg/ml (50 μl)
  • Standard Curve Range: 156.25~10000 pg/ml
  • Standard Curve Gradient: 7 Points
  • Number of Incubations: 2
  • Sample Volume: 50 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 105min
  • Brand:
CAT.NO. : AEH0044
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
MHC class I chain-related genes MICA and MICB are transmembrane glycoproteins that function as ligands for human NKG2D. The two proteins are highly related, sharing 85% amino acid identity, but are also polymorphic. Recognition of MICA or MICB by NKG2D results in the activation of NK cell cytolytic activity and/or cytokine production. MICA/B are minimally expressed on normal cells, but are frequently expressed on or shed from epithelial tumors and can be induced by bacterial and viral infections. MICA and MICB recognition is involved in tumor surveillance, viral infections, and autoimmune diseases.
Typical data
pg/ml O.D. Average Corrected
0.00 0.0202 0.0214 0.0208  
156.25 0.0808 0.0828 0.0818 0.0610
312.50 0.1430 0.1440 0.1435 0.1227
625.00 0.2682 0.2661 0.2672 0.2464
1250.00 0.5125 0.5294 0.5210 0.5002
2500.00 1.0160 1.0370 1.0265 1.0057
5000.00 1.9670 1.9410 1.9540 1.9332
10000.00 3.2950 3.4180 3.3565 3.3357
Precision
Intra-assay Precision Inter-assay Precision
Sample Number S1 S2 S3 S1 S2 S3
22 22 22 6 6 6
Average(pg/ml) 389.9 1231.6 3586.9 373.1 85.4 3682.9
Standard Deviation 21.2 45.6 111.9 4.6 41.5 85.4
Coefficient of Variation(%) 5.4 3.7 3.1 2.5 3.1 2.3

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human MICA into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 94% to 112% with an overall mean recovery of 106%.
Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 469.25-3717.25 100 1351.05

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of IL-12/IL-23 p40 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.