Human Oxytocin-neurophysin 1/OXT ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 1.02 pg/ml (50 μl);4.22 pg/ml (10 μl)
  • Standard Curve Range: 40.96~10000 pg/ml
  • Standard Curve Gradient: 7 Points
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0153
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
This gene encodes a precursor protein that is processed to produce oxytocin and neurophysin I. Oxytocin is a posterior pituitary hormone which is synthesized as an inactive precursor in the hypothalamus along with its carrier protein neurophysin I. Together with neurophysin, it is packaged into neurosecretory vesicles and transported axonally to the nerve endings in the neurohypophysis, where it is either stored or secreted into the bloodstream.
Typical data

pg/ml

O.D.

Average

Corrected

0.00

0.0068

0.0081

0.0075

40.96

0.0280

0.0282

0.0281

0.0207

102.40

0.0630

0.0590

0.0610

0.0536

256.00

0.1461

0.1605

0.1533

0.1459

640.00

0.4384

0.4124

0.4254

0.4180

1600.00

1.1440

1.1410

1.1425

1.1351

4000.00

2.9610

2.8740

2.9175

2.9101

10000.00

4.0079

4.1190

4.0635

4.0560

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

218.3

1133.2

3538.1

221.8

1122.4

3350.1

Standard Deviation

6.8

40.5

130.7

6.3

60.8

184.5

Coefficient of Variation(%)

3.1

3.6

3.7

2.8

5.4

5.5

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human Oxytocin-neurophysin 1/OXT into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 95% to 119% with an overall mean recovery of 103%.
Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 23.53-1127.81 100 175.25
Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of Oxytocin-neurophysin 1/OXT in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.