Human PAI-1/Serpin E1 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 2.18 pg/ml (50 μl);40.00 pg/ml (10 μl)
  • Standard Curve Range: 0.05~40 ng/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 60min
  • Brand:
CAT.NO. : AEHY0160
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
The human serpin superfamily consists of at least 35 members that target not only serine proteases, but also selected cysteine proteases and non-protease proteins. Serpins bind the protease active site resulting in a major conformational rearrangement that traps the enzyme in a covalent acyl-enzyme intermediate. As protease inhibitors, serpins have an array of functions including regulating blood clotting, the complement pathway, extracellular matrix remodeling, and cell motility. They are also involved in activities that extend beyond their ability to inhibit proteases. For instance, they may also regulate blood pressure, angiogenesis, or act as storage/transport proteins.
Typical data

ng/ml

O.D.

Average

Corrected

0.00

0.0073

0.0071

0.0072

0.05

0.0128

0.0128

0.0128

0.0056

0.16

0.0240

0.0223

0.0232

0.0160

0.49

0.0578

0.0546

0.0562

0.0490

1.48

0.1659

0.1523

0.1591

0.1519

4.44

0.5147

0.4948

0.5048

0.4976

13.33

1.5870

1.5630

1.5750

1.5678

40.00

3.8260

3.8630

3.8445

3.8373

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(ng/ml)

0.9

4.1

12.3

0.8

3.8

12.2

Standard Deviation

0.0

0.1

0.4

0.0

0.2

0.3

Coefficient of Variation(%)

3.1

2.8

3.0

4.7

4.2

2.7

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human PAI-1/Serpin E1 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 85% to 101% with an overall mean recovery of 94%.
Sample Values
Sample Matrix Sample Evaluated Range (ng/ml) Detectable (%) Mean of Detectable (ng/ml)
Serum 30 98.03-475.14 100 264.19

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of PAI-1/Serpin E1 in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.