Human TNF beta/Lymphotoxin alpha ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 10.59 pg/ml (50 μl);83.08 pg/ml (10 μl);
  • Standard Curve Range: 40.96~10000 pg/ml
  • Standard Curve Gradient: 7 Points
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0181
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
Lymphotoxin-alpha (LT-alpha ), also known as Tumor Necrosis Factor-beta (TNF-beta ), is a member of the TNF Superfamily. Human LT-alpha /TNF-beta is a 22 kDa protein that shares 73% amino acid sequence identity with mouse and rat LT-alpha /TNF-beta. Secreted LT-alpha forms homotrimers that bind and activate TNF RI/TNFRSF1A, TNF RII/TNFRSF1B, and HVEM/TNFRSF14. LT-alpha /TNF-beta also forms heterotrimers with plasma membrane-localized LT-beta to bind and activate the LT-beta R/TNFRSF3. In addition to its cytotoxic action on tumor cells, LT-alpha /TNF-beta mediates lymph node development, inflammation, and immune function. LT-alpha /TNF-beta is expressed in activated T- and B lymphocytes and contributes to autoimmune disease.
Typical data

pg/ml

O.D.

Average

Corrected

0.00

0.0139

0.0137

0.0138

40.96

0.0270

0.0261

0.0266

0.0128

102.40

0.0495

0.0454

0.0475

0.0337

256.00

0.1006

0.0943

0.0975

0.0837

640.00

0.2308

0.2137

0.2223

0.2085

1600.00

0.5287

0.4955

0.5121

0.4983

4000.00

1.2490

1.1550

1.2020

1.1882

10000.00

2.4840

2.4060

2.4450

2.4312

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

326.8

1415.9

4105.8

226.7

1146.4

3807.0

Standard Deviation

21.7

86.6

262.9

8.1

65.9

68.6

Coefficient of Variation(%)

6.6

6.1

6.4

3.6

5.7

1.8

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human TNF beta/Lymphotoxin alpha into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 92% to 117% with an overall mean recovery of 105%.
Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 n.d.-31.50 25 16.64

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of TNF beta/Lymphotoxin alpha in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. | 浙ICP备2024113709号-3 Sitemap