Human VEGFR2/KDR ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 1.54 pg/ml (50 μl);9.53 pg/ml (10 μl);
  • Standard Curve Range: 6.86~5000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0200
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
VEGF R1 (Flt-1), VEGF R2 (KDR/Flk-1), and VEGF R3 (Flt-4) belong to the class III subfamily of receptor tyrosine kinases (RTKs). All three receptors contain seven immunoglobulin-like repeats in their extracellular domain and kinase insert domains in their intracellular region. They are best known for regulating VEGF family-mediated vasculogenesis, angiogenesis, and lymphangiogenesis. They are also mediators of neurotrophic activity and regulators of hematopoietic development. VEGF R2 is thought to be the primary inducer of VEGF-mediated blood vessel growth, while VEGF R3 plays a significant role in VEGF-C and VEGF-D-mediated lymphangiogenesis.
Typical data

pg/ml

O.D.

Average

Corrected

0.00

0.0221

0.0195

0.0208

6.86

0.0336

0.0305

0.0321

0.0113

20.58

0.0500

0.0446

0.0473

0.0265

61.73

0.1072

0.1073

0.1073

0.0865

185.19

0.2788

0.2483

0.2636

0.2428

555.56

0.7927

0.7507

0.7717

0.7509

1666.67

2.1021

2.0794

2.0908

2.0700

5000.00

4.1378

4.1878

4.1628

4.1420

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

121.47

525.25

1597.38

116.40

515.89

1636.98

Standard Deviation

6.01

32.20

84.55

1.94

15.10

85.29

Coefficient of Variation(%)

4.9

6.1

5.3

1.7

2.9

5.2

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human VEGFR2/KDR into health human serum sample. The un-spiked serum was used as blank in this experiment. The recovery ranged from 99% to 110% with an overall mean recovery of 107%.
Sample Values
Sample Matrix Sample Evaluated Range (ng/ml) Detectable (%) Mean of Detectable (ng/ml)
Serum 30 0.28-24.70 100 9.93

Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of VEGFR2/KDR in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.