Mammal VEGF-C ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 1.82 pg/ml (50 μl)
  • Standard Curve Range: 13.72~10000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 50 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0113
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
*产品价格可能会有所调整,请以品牌方官网实时更新的价格为准,以确保准确性。
Product Details
Background
Vascular endothelial growth factor C (VEGF-C) is a homodimeric ligand of VEGF R3/Flt-4 and is synthesized with N- and C-terminal propeptides. Fully processed VEGF-C containing only the VEGF homology domain can additionally bind and activate VEGF R2/KDR/Flk-1. VEGF-C interactions with VEGF R3 are critical for lymphangiogenesis. Both the ligand and receptor are usually co-expressed at sites of lymphatic vessel sprouting, in the embryo, and in various pathological conditions. Over-expression of VEGF-C in tumor cells induces tumoral lymphatic hyperplasia, neoangiogenesis, and vessel sprouting, resulting in enhanced lymph flow and metastasis to regional lymph nodes.
typical data

pg/ml

O.D.

Average

Corrected

0.00

0.0193

0.0193

0.0193

 

13.72

0.0278

0.0271

0.0275

0.0082

41.15

0.0444

0.0434

0.0439

0.0246

123.46

0.0984

0.0931

0.0958

0.0765

370.37

0.2400

0.2467

0.2434

0.2241

1111.11

0.6659

0.6791

0.6725

0.6532

3333.33

1.7940

1.8210

1.8075

1.7882

10000.00

3.8780

3.7850

3.8315

3.8122

precision

Intra-assay Precision

 

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

240.1

1112.3

3324.8

233.3

1079.7

3258.5

Standard deviation

12.3

50.9

159.1

7.2

37.5

71.2

Coefficient of variation(%)

5.1

4.6

4.8

3.1

3.5

2.2


Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

spike recovery
The spike recovery was evaluated by spiking 3 levels of mammal VEGF-C into health serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 80% to 110% with an overall mean recovery of 91%.
sample values

Sample Matrix

Sample

Evaluated

Range

(pg/ml)

Detectable

%

Mean of Detectable

(pg/ml)

Serum

30

474.36-2997.14

100

1487.71


Serum/Plasma - Thirty samples from apparently healthy volunteers were evaluated for the presence of mammal VEGF-C in this assay. No medical histories were available for the donors.

Sample Matrix

Sample

Evaluated

Range

(pg/ml)

Detectable

%

Mean of Detectable

(pg/ml)

Serum

30

24.68-42.41

100

33.72


Serum/Plasma – Thirty samples from apparently healthy mice were evaluated for the presence of mammal VEGF-C in this assay. No medical histories were available for the donors.

Sample Matrix

Sample

Evaluated

Range

(pg/ml)

Detectable

%

Mean of Detectable

(pg/ml)

Serum

30

12.19-175.72

100

64.70

Serum/Plasma – Thirty samples from apparently healthy rats were evaluated for the presence of mammal VEGF-C in this assay. No medical histories were available for the donors.

New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.